The frame scanning node (VL) of the VM serves to power the frame coils of the deflecting system of a CRT using a sawtooth current.
The RC node is not an energetically intense device — there are no high voltages and high-power impulse currents in it, for this reason malfunctions occur rarely and usually due to aging of the elements or negligence during repair.
The schema contains the following elements:

Diagnostics of faults in the node KR
Defects in the CR node are usually diagnosed from a raster image and have the following symptoms:
Troubleshooting in the CR node begins with
In the absence of synchronization, the passage of a sync pulse is checked before entering the The master oscillator IC may have a malfunction in the control unit.
Vertical linearity distortions are estimated by the image when running test programs, for which use a grid image.
Most of these distortions are due to electrolytic capacitor defects in the boost circuit (C4) or in the master oscillator (C2) - the capacitors lose their nominal capacitance or leakage current appears.
The remaining faults related to the lack of action of adjustments on the front panel when trying to resize the raster vertically or to shift it, may be caused by defects in the potentiometer itself or malfunctions in the control unit. In this case, check the corresponding circuit with an ohmmeter, monitor the voltages with a voltmeter or an oscilloscope and determine the faulty element.
After fixing all the faults that have appeared in the CR node, all the necessary raster parameters are set with the help of trimmers.