You get a bonus - 1 coin for daily activity. Now you have 1 coin

DC source operation modes

Lecture



1. Idle mode corresponds to open source terminals, while the current in the load is absent I = 0, therefore Uxx = E and the power in the load

Pxx = E • I = 0

This mode is used to measure the emf source.

2. The short circuit mode is created when the source terminals are short-circuited, i.e. voltage on the load is zero, because its resistance is equal to zero Rн = 0, therefore, Un = 0 and the short-circuit current is determined: Iкз = E / Rвн = E • Gвн, usually this is an emergency mode at which Iom << Iкз, where Iom is the current for which the element is calculated . Power in the load in this case is equal to zero Рн = I² • Rн = 0.

3. Consistent operation of the source and load, when Rвн = Rн and is characterized by the maximum possible transmission power from the source to the receiver

source current

I = E / (Rvn + Rn)

source power

Pist = E • I = E² / (Rвн + Rн) = E² / 2Rвн

PH = 0.5 • Rist

receiver power (load)

Rn = UI = I² • Rn = RnE² / (Rnn + Rn) ² = E² / 4Rvn

4. Nominal mode - the operation of the source and receiver at the nominal values ​​of the currents and voltages for which they are designed.
created: 2014-09-27
updated: 2019-05-23
132470



Rating 9 of 10. count vote: 2
Are you satisfied?:



Comments


To leave a comment
If you have any suggestion, idea, thanks or comment, feel free to write. We really value feedback and are glad to hear your opinion.
To reply

Electrical Engineering, Circuit design

Terms: Electrical Engineering, Circuit design