You get a bonus - 1 coin for daily activity. Now you have 1 coin

6: Structural Automaton Memory

Lecture



Abstract: The quantitative and qualitative characteristics of the structural automaton memory are considered. The memory elements describe the operation of triggers such as RS triggers, T triggers, D triggers, and JK triggers.
Keywords: memory, automaton, h-formula, abstract automaton, feedback, Moore’s automaton, optimality, completeness, D-flip-flop, stability, logic circuit, RS, JK, rectangle, gate, Product, reset, universality

6.1 General provisions

The memory of the structural automaton is intended for storing the states of the automaton (Fig. 6.1).

  6: Structural Automaton Memory

Fig. 6.1.

The number of memory elements is calculated by the formula   6: Structural Automaton Memory where M is the number of states of the abstract automaton.

The quality characteristic of memory is based on the following provisions:

  1. Since for the correct operation of the circuit, the participation of the output signals of the storage elements in the generation of signals, which are fed to the input of the storage elements at the same time, is not allowed, Moore’s abstract automata should be used as the storage elements.
  2. An automaton, as a memory element, should be with a complete system of transitions and outputs for optimal synthesis.

The completeness of the transition system means that for any pair of states   6: Structural Automaton Memory there is an input signal that takes the automaton from the state a m to the state   6: Structural Automaton Memory .

The completeness of the output system means that each state has its own output signal. From this it follows that the output signals, as it were, can be identified with the states of the automaton.

An example of an automaton with a complete system of transitions and exits is given in Table 6.1.

Table 6.1.
U n U 1 U 2 U 3
Z f \ A m A 1 A 2 A 3
Z 1 A 1 A 3 A 1
Z 2 A 2 A 1 A 3
Z 3 A 3 A 2 A 2
Table 6.2.
The initial state Input signal State transitions
A 1 Z 1 A 1
A 1 Z 2 A 2
A 1 Z 3 A 3
A 2 Z 2 A 1
A 2 Z 3 A 2
A 2 Z 1 A 3
A 3 Z 1 A 1
A 3 Z 3 A 2
A 3 Z 2 A 3

Having considered each transition according to table 6.1, it is possible to present this information in a slightly different form, as shown in table 6.2.

6.2. Triggers.

As memory elements most often triggers are used. A trigger is an element of electronic circuits that can be in any of two stable states, as well as repeatedly switch from one state to another. For logic, two trigger states correspond to a logical "1" and a logical "0". Thus, triggers are single-bit memory elements.

Consider the most widely applicable triggers, such as RS-triggers, T-triggers, D - triggers and JK - triggers.

6.2.1. RS triggers.
  6: Structural Automaton Memory

Fig. 6.2.

On charts, triggers are denoted as a rectangle divided into two fields. In the left field are the names of the inputs of the triggers (Fig. 6.2, a), in the right letter "T" there is a trigger with direct output   6: Structural Automaton Memory and inverse   6: Structural Automaton Memory .

Fig. 6.2, b shows the implementation of the trigger using the NAND gate.

Work RS-trigger presented in Table 6.3.

Table 6.3.
Inputs States
RS 0 one Operation
0 0 0 one Storage
0 1 one one Set to 1
ten 0 0 Set to 0
eleven Forbidden

If the trigger is set to 1, then this value remains in it until a reset is effected (a signal is sent to the R -reset input) or the power is turned off. If the trigger is set to 0, then this value is stored in it until a signal is sent to the input S -set. Simultaneous sending of signals to both inputs of the trigger is prohibited, since in this case the situation is ambiguous. In more complex triggers, such as JK-triggers, this situation is excluded

  6: Structural Automaton Memory

Fig. 6.3.

Denote the excitation function   6: Structural Automaton Memory and   6: Structural Automaton Memory which arrive respectively at the R and S inputs of the trigger (Figure 6.3) (Table 6.4). The work of the trigger will be represented by a transition table similarly to Table 6.2, i.e. We describe all transitions from the initial state of the trigger to possible transition states (Table 6.5).

Table 6.4.
  6: Structural Automaton Memory
RS 0 one
0 0 0 one
0 1 one one
ten 0 0
eleven - -
Table 6.5.
  6: Structural Automaton Memory   6: Structural Automaton Memory   6: Structural Automaton Memory
0 00v10 0
0 0 1 one
one 0 1 0
one 00v01 one
Table 6.6.
  6: Structural Automaton Memory   6: Structural Automaton Memory   6: Structural Automaton Memory
0 - 0 0
0 0 1 one
one ten 0
one 0 - one

Analyzing the table 6.5, we see that the trigger from the state "0" to the state "0" passes when both inputs are fed "0" or input S "0", and at the input R can be "1", that is, at the input S always with this transition must be "0", and at the input R any signal. Thus, the excitation functions at the transition of the trigger from "0" to "0" are:   6: Structural Automaton Memory ,   6: Structural Automaton Memory "-" (any signal). The trigger transition from the state "0" to the state "1" occurs if the input S is "1" and the input R must be "0", that is, the excitation function when the trigger transitions from "0" to "1":   6: Structural Automaton Memory etc. All transitions and the corresponding excitation functions of the RS-trigger are shown in Table 6.6. This table is sometimes referred to as the RS Trigger excitation function table.

6.2.2. T - trigger (trigger with counting input)
Table 6.7.
  6: Structural Automaton Memory
T 0 one
0 0 one
one one 0
Table 6.8.
  6: Structural Automaton Memory   6: Structural Automaton Memory   6: Structural Automaton Memory
0 0 0
0 one one
one one 0
one 0 one
Table 6.9.
  6: Structural Automaton Memory
D 0 one
0 0 0
one one one
Table 6.10.
  6: Structural Automaton Memory   6: Structural Automaton Memory   6: Structural Automaton Memory
0 0 0
0 one one
one 0 0
one one one

Clocked trigger, the output of which "switches", that is, changes the current state to the opposite with each receipt of the active signal "1". The operation of the T-trigger is described in Table 6.7, the representation of which for the explicit mapping of the excitation function of the T Trigger is given in Table 6.8.   6: Structural Automaton Memory , only when the state of the automaton goes from 0 to 1 or from 1 to 0.

  6: Structural Automaton Memory

Fig. 6.4.

6.2.3. D-trigger (delay element)

D-trigger (Fig.6.5) has the installation modes "1" and "0" and implements the function of the time delay (Table 6.8). As you can see from the tab.6.9 function of Fig.6.5 excitation of D - trigger   6: Structural Automaton Memory coincides with the state in which the trigger switches.

  6: Structural Automaton Memory

Fig. 6.5.

6.2.4. JK trigger
  6: Structural Automaton Memory

Fig. 6.6.

The most widely used is the universal JK-trigger (Fig.6.6). Work JK-trigger presented in Table 6.11. Simultaneous signaling at both inputs of the trigger causes it to work as a T-trigger, that is, if the trigger has been set to "0", then it switches to "1" and vice versa.

Table 6.11.
Inputs States
Jk 0 one Operation
0 0 0 one Storage
0 1 0 0 Set to "0"
ten one one Set to "1"
eleven one 0 Switching

Denote the excitation function   6: Structural Automaton Memory and   6: Structural Automaton Memory which arrive respectively at the J and K inputs of the trigger (Fig.6.6) and (Table 6.11). The work of the trigger will be represented by a table (Table 6.12) and tables of excitation functions (Table 6.13) and (Table 6.14).

Table 6.12.
  6: Structural Automaton Memory
Jk 0 one
0 0 0 one
ten one one
eleven one 0
0 1 0 0
Table 6.13.
  6: Structural Automaton Memory   6: Structural Automaton Memory   6: Structural Automaton Memory
0 00v01 0
0 10v11 one
one 01v11 0
one 00v10 one
Table 6.14.
  6: Structural Automaton Memory   6: Structural Automaton Memory   6: Structural Automaton Memory
0 0 - 0
0 one - one
one - one 0
one - 0 one

Analyzing the table 6.11, we see that the trigger from the state "0" to the state "1" passes when the input "K" is "1", and any signal can be input J. The transition of the trigger from the state "1" to the state "0" occurs if the input J is "1" and the input K is any signal. Thus, the excitation functions are as follows:   6: Structural Automaton Memory , at transition of the trigger from "1" to "0" and   6: Structural Automaton Memory at transition of the trigger from "0" in "1".